Orion offers a wide range of E1 and T1 Groomers for non-intrusive monitoring applications. The VCL-MegaConnect, E1 and T1, Hi-Z Monitoring Groomers may be used for non-intrusive monitoring of "live" E1 and T1 traffic links, non-intrusively, through a high impedance monitoring point on a patch panel or a DDF. The equipment also allows the user to groom the selected time-slots carrying the monitored data to selected E1 or T1 normal impedance ports which can be connected to protocol analyzers, probes, test equipment, billing servers etc.

Solutions offered and available for Hi-z Non-Intrusive Monitoring applications are:

64 Port Plus - E1 Monitoring Groomer  64 Port Plus - T1 Monitoring Groomer  |
|
 64 Port E1 Hi-Z Monitoring Groomer  |  64 Port T1 Hi-Z Monitoring Groomer  |
|  32 Port E1 Hi-Z Monitoring Groomer  |  32 Port T1 Hi-Z Monitoring Groomer  |
|  16 Port E1 Hi-Z Monitoring Groomer  |  16 Port T1 Hi-Z Monitoring Groomer  |
 

64 Port Plus - T1 Monitoring GROOMER
  The VCL-MegaConnect, 64 Port Plus - T1 Monitoring Groomer is suitable for non-intrusive monitoring of upto 32, "live" T1 traffic links, bidirectionally (i.e. in both transmit and receive directions through its 64 T1 receivers) through a high impedance (Hi-Z) path. Additionally, the equipment also provides 16 output T1 ports that shall connect the aggregated time-slots which have been non-intrusively "monitored" from the 32, "live" T1 traffic links to the user's protocol analysers, test probes, etc.
   

Product Brochure (PDF 368 KB)

   
64 Port Plus - E1 Monitoring GROOMER
  The VCL-MegaConnect, 64 Port Plus - E1 Monitoring Groomer is suitable for non-intrusive monitoring of upto 32, "live" E1 traffic links, bidirectionally (i.e. in both transmit and receive directions through its 64 E1 receivers) through a high impedance (Hi-Z) path. Additionally, the equipment also provides 16 output E1 ports that shall connect the aggregated time-slots which have been non-intrusively "monitored" from the 32, "live" E1 traffic links to the user's protocol analysers, test probes, etc.
   

Product Brochure (PDF 176 KB)

   
64 Port E1 Hi-Z Monitoring (Hi-Impedance) GROOMER
  The 64 Port E1 VCL-MegaConnect Groomer is suitable for non-intrusive monitoring of upto 30, "live" E1 traffic links, bidirectionally (i.e. in both transmit and receive directions through it's 60 E1 receivers) through a high impedance (Hi-Z) path. Additionally the equipment also provides 4 E1 ports that shall connect the aggregated time-slots which have been non-intrusively "monitored" from the 30, "live" E1 traffic links to the test equipment protocol analysers/test probes etc. The 64 Port E1 VCL-MegaConnect Groomer offers bidirectional monitoring and unidirectional monitoring modes
   

Product Brochure PDF (192 KB)

   
64 Port T1 Hi-Z Monitoring (Hi-Impedance) GROOMER
 

VCL-MegaConnect, T1 x upto 64 port Hi-Z Monitoring Groomer is available for special non-intrusive monitoring (high impedance) applications in which T1 ports can be connected to monitoring / billing equipment for non-intrusive monitoring of live traffic or signaling, required by billing servers etc. In the monitoring mode the groomer provides the user a total of 32, T1 Ports. 30, T1 ports shall connect to the “live traffic” T1 links which are to be monitored, non-intrusively (Hi-Z) in both transmit and receive directions. 2, T1 Ports shall connect to the monitoring equipment, such as billing servers etc.

   

Product Brochure PDF (144 KB)

   
32 Port E1 Hi-Z Monitoring (Hi-Impedance) GROOMER
  VCL-MegaConnect, the E1 x 32 port Hi-Z Monitoring Groomer is available for special non-intrusive monitoring (high impedance) applications in which E1 ports can be connected to monitoring / billing equipment for non-intrusive monitoring of live traffic or signaling, required by billing servers etc.
   

Product Brochure PDF (192 KB)

   
32 Port T1 Hi-Z Monitoring (Hi-Impedance) GROOMER
  VCL-MegaConnect, the T1 x 32 port Hi-Z Monitoring Groomer is available for special non-intrusive monitoring (high impedance) applications in which T1 ports can be connected to monitoring / billing equipment for non-intrusive monitoring of live traffic or signaling, required by billing servers etc.
   

Product Brochure PDF (192 KB)

   
16 Port E1 Hi-Z Monitoring (Hi-Impedance) GROOMER
  VCL-MegaConnect, the E1 16 port Hi-Z Monitoring Groomer is available for non-intrusive live traffic monitoring (high impedance) applications in which E1 (or T1) ports can be connected to monitoring / billing equipment for non-intrusive monitoring of live traffic or signaling, required by billing servers etc.
   

Product Brochure PDF (192 KB)

   
16 Port T1 Hi-Z Monitoring (Hi-Impedance) GROOMER
  VCL-MegaConnect, the T1 16 port Hi-Z Monitoring Groomer is available for special non-intrusive monitoring (high impedance) applications in which T1 (or E1) ports can be connected to monitoring / billing equipment for non-intrusive monitoring of live traffic or signaling, required by billing servers etc
   

Product Brochure PDF (192 KB)

Technical specifications are subject to change without notice.
All brand names and trademarks are the property of their respective owners.

TOP

 

GSM Gateway / GSM Channel Banks

Echo Cancellers and Voice Quality Enhancement

Digital Access Cross Connect Switch (DACS)

STM SDH Multiplexer
Multiplexers
Optical Transmission
E1, T1, E3, DS3, Ethernet Converters
APS (1+1) Automatic
Protection Switch
::   Application Diagram  ::
 
Home    |   What's New   |   About Us   |   Contact Us   |   Products   |    Press   |   E-mail

Orion Telecom Networks, Inc.
16810, Avenue of the Fountains,
Suite # 108, Fountain Hills, AZ 85268 U.S.A.
Phone: +1 480-816-8672,  Fax: +1 480-816-0115
E-mail: sales@oriontelecom.com